Modelio Nr.UY Series Line Interactive UPS(2000-3000VA)

Prekės ženklas„Unitronic“ galia

Warranty Period3months-1year, 3years, Other

Place Of OriginChina

PhaseSingle Phase

ProtectionLightning, Short Circuit, Overvoltage, Overcurrent, Unbalanced Loads

WeightOther

Types OfLine Interactive

Scope Of ApplicationComputer, Security / Monitoring / Alarm, Military, Medical, Instrumentation, Networking, Telecommunications

Capacity2000/3000VA

Pakavimas > Pristatymas
Pardavimo vienetai : Piece/Pieces
Pakuotės tipas : dėžutės pakuotė
Paveikslėlio pavyzdys :
Prekės aprašymas

„UY Series Line Interactive UPS“ yra neprisijungus. Jame yra žemos įtampos apsaugos, sistemos palaikymas, naudojant pažangų procesoriaus valdymą, LED ir LCD skydelius, iš kurių galima rinktis, ir yra atsarginės UPS, tinkantys mažiems elektroniniams įrenginiams. Jis turi gerą išvaizdą ir gerą našumą, yra labai vertingas produktas, skirtas kompiuteriams, oro kondicionieriams ir POS mašinoms, kurias naudoja namų biurai ir mažos įmonės.


Line Interactive UPS


MODEL

UY2000

UY2000

UY3000

Capacity

2000VA/1200W

2000VA/1200W

3000VA/1800W

INPUT

Input Voltage

110/120Vac or 220/230/240Vac

Input Voltage Range

84-145Vac or 175-275Vac

Frequency Range

45-65Hz

OUTPUT

Output Voltage

110/120Vac or 220/230/240Vac

Output Voltage Range

102-132Vac or 198-242Vac

Output Frequency

60±0.5Hz or 50±0.5Hz (Battery mode)

Output wave Form

PWM (Battery mode)

Transfer Time

Typical 2-6ms, 10ms max.

BATTERY

QTY & Capacity of Battery

12V/9Ahx2pcs

12V/7Ahx4pcs

12V/9Ahx4pcs

Charging Period

4-6 hours recover to 90% capacity

PROTECTION

Full Protection

Low voltage & overload & short circuit protection

INDICATOR

LCD or LED

Optional

INTERFACE

USB/RJ45 or None

Optional, support windows XP/Vista, Windows 7/8, Linux, Unix, and MAC

ENVIRONMENT

Operation Temperature

 0-40

Humidity

20-90% (Non-condensing)

Noise Level

40dB(1m away)

Altitude

The altitude should not exceed 1000m,and the height above 1000m

should be reduced to a maximum of 4000m.Refer to IEC62040

PHYSICAL

Net Weight (kg)

14.7

17.8

20

Unit Dimension (mm)

345x122x192

412x145x210